中文(繁體)
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
American Journal of Perinatology 1995-May

From biochemical to biophysical placental function tests in fetal surveillance.

只有註冊用戶可以翻譯文章
登陸註冊
鏈接已保存到剪貼板
B Arabin
V Ragosch
A Mohnhaupt

關鍵詞

抽象

Radioimmunoassays of human placental lactogen and estriol levels in the maternal plasma, ultrasound biometry of the abdominal diameter (AD), pulsed Doppler measurements of uteroplacental arteries, the common carotid artery (CCA), and the umbilical artery (UA) and fetal heart rate monitoring were simultaneously performed in 219 risk pregnancies from 26 weeks' onward at regular intervals. The prognostic value of all tests to predict small for gestational age infants (SGA) and fetal distress was evaluated simultaneously. Receiver operator characteristic allowed the simultaneous comparison of all methods: The AD was most predictive for early detection of SGA, even more than uteroplacental blood flow. Fetal blood flow redistribution expressed as a ratio of the resistance index of CCA/UA was the most significant test for detection of fetal distress later in pregnancy, even more than antenatal cardiotocography. Considering cutoff levels used in clinical routine, the sensitivity and specificity of the fetal AD in detecting intrauterine growth retardation more than 28 days before birth, were 71 and 81%, respectively. Pulsed Doppler measurements of CCA/UA less than 7 days before the delivery had a sensitivity and specificity of 83 and 90%, respectively. Our results demonstrate the historical change in fetal surveillance within one study group: If accurate routine ultrasound is available, the use of biochemical placental function tests is not justified, a procedure that is already accepted in nearly all perinatal centers. Fetal cerebral versus umbilical blood flow measurements should be applied as a tool to measure fetal blood flow redistribution in small fetuses to predict most precisely the risk for poor outcome and perinatal hypoxia.

加入我們的臉書專頁

科學支持的最完整的草藥數據庫

  • 支持55種語言
  • 科學支持的草藥療法
  • 通過圖像識別草藥
  • 交互式GPS地圖-在位置標記草藥(即將推出)
  • 閱讀與您的搜索相關的科學出版物
  • 通過藥效搜索藥草
  • 組織您的興趣並及時了解新聞研究,臨床試驗和專利

輸入症狀或疾病,並閱讀可能有用的草藥,輸入草藥並查看其所針對的疾病和症狀。
*所有信息均基於已發表的科學研究

Google Play badgeApp Store badge