中文(繁體)
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
American journal of contact dermatitis : official journal of the American Contact Dermatitis Society 1996-Sep

Resorcinols and catechols: a clinical study of cross-sensitivity.

只有註冊用戶可以翻譯文章
登陸註冊
鏈接已保存到剪貼板
T E Knight
P Boll
W L Epstein
A K Prasad

關鍵詞

抽象

BACKGROUND

All allergic contact dermatitis caused by Philodendron species is common in the Hawaiian islands, and Toxicodendron species are the most common causes of plant-induced allergic contact dermatitis in North America.

OBJECTIVE

The purpose of this study was to determine the incidence of cross-sensitivity between these plant species.

METHODS

Alkylresorcinols (pentadec[en]yl and heptadec[en]ylresorcinols) were isolated and purified from extracts of Hawaiian-grown Philodendron scandens subspecies scandens and Philodendron lacerum. Alkylcatechols (mixtures of pentadec[en]ylcatechols from an extract of Toxicodendron radicans (poison ivy) were obtained from the Division of Biologics Standards (National Institutes of Health, Bethesda, MD). Seventeen patients from Hawaii and 8 patients from northern California were skin tested with 5 microL (concentrations, 1 to .001 mg/mL) of each allergen applied to the flexor forearm. The test sites remained open and were graded at 72, 96, and 144 hours. All 8 patients from California were naive to Philodendron species, and 8 patients from Hawaii were naive to Toxicodendron species.

RESULTS

No cross-reactivity occurred in patients who were Philodendron sensitive and Toxicodendron naive when tested to the homologous Toxicodendron catechols. Conversely, with one exception, no cross-reactivity occurred in patients who were Toxicodendron sensitive and Philodendron naive when tested to homologous Philodendron naive when tested to homologous Philodendron resorcinols.

CONCLUSIONS

Patients who are sensitive to Philodendron species (or other resorcinol-containing plants) may not necessarily be cross-sensitive to Toxicodendron species and vice versa.

加入我們的臉書專頁

科學支持的最完整的草藥數據庫

  • 支持55種語言
  • 科學支持的草藥療法
  • 通過圖像識別草藥
  • 交互式GPS地圖-在位置標記草藥(即將推出)
  • 閱讀與您的搜索相關的科學出版物
  • 通過藥效搜索藥草
  • 組織您的興趣並及時了解新聞研究,臨床試驗和專利

輸入症狀或疾病,並閱讀可能有用的草藥,輸入草藥並查看其所針對的疾病和症狀。
*所有信息均基於已發表的科學研究

Google Play badgeApp Store badge