Journal of Medical Radiation Sciences 2020-Feb

Updated Australian diagnostic reference levels for adult CT.

只有註冊用戶可以翻譯文章
登陸註冊
鏈接已保存到剪貼板
Kam Lee
Toby Beveridge
Masoumeh Sanagou
Peter Thomas

關鍵詞

抽象

In 2018, ARPANSA published updated national DRLs for adult CT, which were first published in 2012, and augmented the national DRL categories. This paper presents the updated national DRLs and describes the process by which they were produced.Examine patient survey data submitted to the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) National Diagnostic Reference Level Service (NDRLS). Determine the quartiles of the distributions of median survey dose metrics with categorisation by procedure type. Engage a liaison panel representing the radiology professions to review procedure categories and recommend revised national DRLs. The revised NDRL procedure categories are: head (non-contrast brain (trauma/headache)), cervical spine (Non-contrast (trauma)), soft-tissue neck (post-contrast (oncology)), chest (post-contrast (oncology)), abdomen-pelvis (post-contrast (oncology)), kidney-ureter-bladder (non-contrast (suspected renal colic)), chest-abdomen-pelvis (post-contrast (oncology)) and lumbar spine (non-contrast (degenerative pain)).The existing six procedure categories were revised and refined. Updated Australian national diagnostic reference levels for adult CT were recommended and endorsed for eight procedure categories: head (52 mGy/880 mGycm), cervical spine (23 mGy/470 mGycm),soft-tissue neck (17 mGy/450 mGycm), chest (10 mGy/390 mGycm), abdomen-pelvis (13 mGy/600 mGycm), kidney-ureter-bladder (13 mGy/600 mGycm), chest-abdomen-pelvis (11 mGy/940 mGycm) and lumbar spine (26 mGy/670 mGycm). The updated national DRLs are between 12 and 26% lower than the previous DRLs for dose-length product and between 13 and 63% lower for volume computed tomography dose index.Australian national DRLs for adult CT have been reviewed and revised. The revised national DRLs are lower, better reflecting current practice among imaging facilities in Australia. The revised Australian national DRLs are similar to those in other developed countries.

加入我們的臉書專頁

科學支持的最完整的草藥數據庫

  • 支持55種語言
  • 科學支持的草藥療法
  • 通過圖像識別草藥
  • 交互式GPS地圖-在位置標記草藥(即將推出)
  • 閱讀與您的搜索相關的科學出版物
  • 通過藥效搜索藥草
  • 組織您的興趣並及時了解新聞研究,臨床試驗和專利

輸入症狀或疾病,並閱讀可能有用的草藥,輸入草藥並查看其所針對的疾病和症狀。
*所有信息均基於已發表的科學研究

Google Play badgeApp Store badge