Polish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)

tantalum/zmęczenie

Link zostanie zapisany w schowku
15 wyniki

Experimental lumbar spine fusion with novel tantalum-coated carbon fiber implant.

Tylko zarejestrowani użytkownicy mogą tłumaczyć artykuły
Zaloguj się Zarejestruj się
Implants of carbon fiber composite have been widely used in orthopedic and spinal surgeries. However, studies using carbon fiber-reinforced cages demonstrate frequent appearance of fibrous layer interposed between the implant and the surrounding bone. The aim of the present study was to test the

Peculiarities of circulatory system response on influence of modern tantalum manufacture factors in workers.

Tylko zarejestrowani użytkownicy mogą tłumaczyć artykuły
Zaloguj się Zarejestruj się
Objective of this study was to examine functional condition of cardiovascular system among workers at "Ulba Metallurgical Plant" JSC (located in Ust-Kamenogorsk, Eastern Kazakhstan)--one of the world largest enterprises with the full production cycle from processing of tantalum containing raw

Unprecedented simultaneous enhancement in damage tolerance and fatigue resistance of zirconia/Ta composites.

Tylko zarejestrowani użytkownicy mogą tłumaczyć artykuły
Zaloguj się Zarejestruj się
Dense (>98 th%) and homogeneous ceramic/metal composites were obtained by spark plasma sintering (SPS) using ZrO2 and lamellar metallic powders of tantalum or niobium (20 vol.%) as starting materials. The present study has demonstrated the unique and unpredicted simultaneous enhancement in toughness

Phase Exchange Driven Wake-Up and Fatigue in Ferroelectric Hafnium Zirconium Oxide Films.

Tylko zarejestrowani użytkownicy mogą tłumaczyć artykuły
Zaloguj się Zarejestruj się
Ferroelectric hafnium zirconium oxide holds great promise for a broad spectrum of CMOS compatible and scaled microelectronic applications, including memory, low voltage transistors, and infrared sensors, among others. An outstanding challenge hindering implementation of this material is polarization
Background and purpose - Long-term fixation of cemented femoral stems relies on several factors including cement adhesion and fatigue. Hi-Fatigue is a newer third-generation bone cement with low-viscosity properties at room temperature, good mechanical strength, and stable bone-cement interface in a

Direct laser processing of a tantalum coating on titanium for bone replacement structures.

Tylko zarejestrowani użytkownicy mogą tłumaczyć artykuły
Zaloguj się Zarejestruj się
Recently tantalum is gaining more attention as a new metallic biomaterial as it has been shown to be bioactive and biologically bonds to bone. However, the relatively high cost of manufacture and an inability to produce a modular all Ta implant has limited its widespread acceptance. In this study we

Structure, metallurgy, and mechanical properties of a porous tantalum foam.

Tylko zarejestrowani użytkownicy mogą tłumaczyć artykuły
Zaloguj się Zarejestruj się
This study evaluated a porous tantalum biomaterial (Hedrocel) designed to function as a scaffold for osseous ingrowth. Samples were characterized for structure, Vickers microhardness, compressive cantilever bending, and tensile properties, as well as compressive and cantilever bending fatigue. The

Fatigue performance of additively manufactured meta-biomaterials: The effects of topology and material type.

Tylko zarejestrowani użytkownicy mogą tłumaczyć artykuły
Zaloguj się Zarejestruj się
Additive manufacturing (AM) techniques enable fabrication of bone-mimicking meta-biomaterials with unprecedented combinations of topological, mechanical, and mass transport properties. The mechanical performance of AM meta-biomaterials is a direct function of their topological design. It is,

Additively manufactured porous tantalum implants.

Tylko zarejestrowani użytkownicy mogą tłumaczyć artykuły
Zaloguj się Zarejestruj się
The medical device industry's interest in open porous, metallic biomaterials has increased in response to additive manufacturing techniques enabling the production of complex shapes that cannot be produced with conventional techniques. Tantalum is an important metal for medical devices because of

Elastic deformation properties of implanted endobronchial wire stents in benign and malignant bronchial disease: A radiographic in vivo evaluation.

Tylko zarejestrowani użytkownicy mogą tłumaczyć artykuły
Zaloguj się Zarejestruj się
OBJECTIVE To evaluate the long-term mechanical behavior in vivo of expandable endobronchial wire stents, we imaged three different prostheses in the treatment of tracheobronchial disease. METHODS Six patients with bronchial stenoses (three benign, three malignant) underwent insertion of metallic

Microstructural changes within similar coronary stents produced from two different austenitic steels.

Tylko zarejestrowani użytkownicy mogą tłumaczyć artykuły
Zaloguj się Zarejestruj się
Coronary heart disease has become the most common source for death in western industrial countries. Since 1986, a metal vessel scaffold (stent) is inserted to prevent the vessel wall from collapsing [Puel, J., Joffre, F., Rousseau, H., Guermonprez, B., Lancelin, B., Valeix, B., Imbert, G.,

[Biodeterioration and corrosion of metallic implants and prostheses].

Tylko zarejestrowani użytkownicy mogą tłumaczyć artykuły
Zaloguj się Zarejestruj się
The use of surgical implants and prosthetic devices to replace the original function of different components of the human biological system is a well established tradition in the history of medicine. Currently, one of the most prevalent points of view in dealing with this subject, is that of

Clinical device-related article surface characterization of explanted endovascular stents: evidence of in vivo corrosion.

Tylko zarejestrowani użytkownicy mogą tłumaczyć artykuły
Zaloguj się Zarejestruj się
Limited information exists regarding the in vivo stability of endovascular stents. Nine excised human vascular segments with implanted stents (n = 16) manufactured from stainless steel, nickel-titanium, tantalum, and cobalt-based alloys were analyzed. The stent/tissue components were separated using

Acetabular distraction: an alternative for severe defects with chronic pelvic discontinuity?

Tylko zarejestrowani użytkownicy mogą tłumaczyć artykuły
Zaloguj się Zarejestruj się
BACKGROUND Stabilization of a pelvic discontinuity with a posterior column plate with or without an associated acetabular cage sometimes results in persistent micromotion across the discontinuity with late fatigue failure and component loosening. Acetabular distraction offers an alternative

Biomaterials in Spinal Implants: A Review.

Tylko zarejestrowani użytkownicy mogą tłumaczyć artykuły
Zaloguj się Zarejestruj się
The aim to find the perfect biomaterial for spinal implant has been the focus of spinal research since the 1800s. Spinal surgery and the devices used therein have undergone a constant evolution in order to meet the needs of surgeons who have continued to further understand the biomechanical
Dołącz do naszej strony
na Facebooku

Najbardziej kompletna baza danych ziół leczniczych poparta naukowo

  • Działa w 55 językach
  • Ziołowe leki poparte nauką
  • Rozpoznawanie ziół na podstawie obrazu
  • Interaktywna mapa GPS - oznacz zioła na miejscu (wkrótce)
  • Przeczytaj publikacje naukowe związane z Twoim wyszukiwaniem
  • Szukaj ziół leczniczych po ich działaniu
  • Uporządkuj swoje zainteresowania i bądź na bieżąco z nowościami, badaniami klinicznymi i patentami

Wpisz objaw lub chorobę i przeczytaj o ziołach, które mogą pomóc, wpisz zioło i zobacz choroby i objawy, na które są stosowane.
* Wszystkie informacje oparte są na opublikowanych badaniach naukowych

Google Play badgeApp Store badge